[[TitleIndustry]]

Induction door configuration and installation instructions

Date:Nov 26, 2020

Induction door configuration and installation instructions


Introduction Induction doors include translational induction doors and flat opening induction doors. The "sensing" here refers to a door opening mode in automatic doors. When a person or object approaches the door, the door will open automatically. Sensor doors are widely used in shops, hotels, institutions, high-end office buildings


Induction door configuration and installation instructions

The induction door includes a sliding induction door and a flat opening induction door. The "sensing" here refers to a door opening mode in automatic doors. When a person or object approaches the door, the door will open automatically. Sensor doors are widely used in shops, hotels, institutions, high-end office buildings and other places. An integral part of the induction door. Main controller: It is the command center of the automatic door. Through a large-scale integrated block with internal instruction programs, it sends out corresponding instructions to direct the operation of motors or electric lock systems; at the same time, people use the main controller to adjust the opening speed and opening range of the door leaf And other parameters. Induction detector: Responsible for collecting external signals, just like people's eyes, when a moving object enters its working range, it will give a pulse signal to the main controller. Power motor: Provides the main power for opening and closing the door, and controls the acceleration and deceleration of the door leaf. Door leaf running track: Just like a train track, the wheel system of the door leaf spreader restrains the door leaf to travel in a specific direction. Door spreader walking wheel system: used to hang movable door leaves, and at the same time drive the door leaves to run under power traction. Timing belt (some manufacturers use V-belt): used to transmit the power produced by the motor, and to pull the wheel system of the door spreader. Lower guide system: It is a guide and positioning device for the lower part of the door leaf to prevent the door leaf from swinging back and forth during operation. Sensor doors are widely used in hotels, hotels, banks, office buildings, hospitals, shops, etc., with a very wide range of applications.


Induction door


In high-end hotels and office buildings, you can choose high-sensitivity sensors; in banks and shops on the sidewalks where people often pass by, choose narrow-area sensors. In high-end hotels and other places, it is necessary to prevent people from being trapped by induction. You can choose to install an infrared sensor for preventing people from being trapped. In order to ensure that the automatic door can work normally even in the event of a power failure, a backup power supply can be equipped. According to requirements, the exterior wall sensor door automatically obtains the door opening signal when a person approaches the door, and then opens the door through the drive system. At the same time, when the person leaves the door, the door is closed, and the entire process can be automatically controlled. There are many users who use the induction door. The following is a brief introduction to its daily use precautions. The power supply must be set up with a dedicated line, and it is strictly forbidden to use it with other electrical appliances. The product can be used only after it is installed firmly and qualified. The control box must be installed in a dry and ventilated location. It is strictly prohibited to approach high-power radio equipment to avoid affecting normal operation. When using the control buttons, do not use excessive force or excessive force to avoid damage. When the door is running, it is strictly forbidden for people and vehicles to stay on the guide rail. The operator should keep an eye on the operation of the door at any time to avoid accidents. The track should be cleaned frequently to prevent debris from affecting the operation. The drive should be filled with grease at least once a year. The chain of the induction door should be filled with lubricant and checked frequently. All parts are worn and severely worn parts should be repaired or replaced in time. The induction door should be opened and closed lightly and slowly. It is forbidden to push or pull violently to cause damage. When the product fails, please notify the professional maintenance personnel for maintenance in time, non-professional Personnel shall not open it without authorization.


Previous: How to install the garage door opener

Next: Which one is better for swiping card automatic doors?